To get the complete mil hdbk 217f notice 2 document, download these 3 pdf files. Purpose mil h dbk 162a is intended to provide, in concise and convenient form, f a c t u a 1 data to familiarize maintenance and engineering personnel and government contractors with the characteristics and physical makeup of radar equipments use within the department of. The control of electrostatic discharge can easily be implemented by employing. The 217 plus prediction module incorporates the component failure rate prediction models developed by the riac reliability information analysis center.
This handbook provides fundamental guidance to engineer and install electronic systems that process or communicate classified information. Each section in the airworthiness certification criteria is matched with corresponding title 14, code of federal regulations reference 14cfr reference and joint service specification guides jssg. Milhdbk263b electrostatic discharge control handbook for. The 217 plus is updated to develop a replacement prediction methodology for mil hdbk 217 reliability prediction of electronic equipment, the widely used approach since 1995. Front matter mil hdbk 162a volume 1 of 2 15 december 1965 introduction 1. This military handbook is approved for use by all departments and agencies of the department of defense. It is the first complete revision of the handbook since 2004 and supersedes the mil hdbk 1222d with changes 1 through 3 released in march 2008. This file contains additional information such as exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. Proposed draft mil hdbk 61b 10 september 2002 superseding mil hdbk 61ase 7 february 2001 military handbook configuration management guidance amsc na area cman distribution statement a. This handbook provides guidance for developing, implementing and monitoring an esd control program in accordance with the requirements of milstd1686. Case temperature the case temperature t c is the temperature measured typically the. Milstd1695 specifically addresses relative humidity levels in the range of 30.
The goal of whole building design is to create a successful highperformance building by applying an integrated design and team approach to the project during the planning and programming phases. Mil hdbk 172f volume 2, foreword table of contents ii foreword 1. A work breakdown structure wbs provides a consistent and visible framework for. Mil hdbk 516b 26 september 2005 superseding mil hdbk 516a 5 february 2004 department of defense handbook airworthiness certification criteria this handbook is for guidance only. Spad will ensure files containing pii data stored on a network shared. It contains guidance which will, when used in conjunction with departmentagency directives, aid in the protection of such information by reducing the probability of hostile interception and exploitation. Mil hdbk 199c 14 august 20 superseding mil hdbk 199b. Mil m8555 mil m1 1745 mil m231 melc486 mflw855 mflm18012 mil t23991 sheeting and tape, reflective. Milhdbk263b and meet the static delay rate provision of. The application of mil std1686 requirements will result in continuous esd controls throughout the lifetime of esd susceptible parts, assemblies, and equipment. Mil hdbk 232a redblack engineeringinstallation guidelines, with notices 12.
Heating, venting, air conditioning, and dehumidifying. In addition, the complete listing of 14cfr reference advisory circulars was. Milhdbk232a redblack engineeringinstallation guidelines. Milhdbk1190 facility planning and design guide document. Milhdbk263b electrostatic discharge control handbook. Acquisition activity the acquisition activity is the government office or contractor organization acquiring the equipment, system, or subsystem. Have you tried looking in mil hdbk 263b, electrostatic discharge control handbook for protection of electrical and electronic parts, assemblies and equipment. Eia standard 649, national consensus standard on configuration management was approved by ansi on 10 july 1998 and was officially issued as ansieia6491998 in august 1998. The file size is to big, otherwise i would of attached a copy. Military directives, handbooks and standards related to reliability. Retain the pages of this notice and insert before the table of contents.
This draft dated 31 march 1997, prepared by the cals. These documents can be downloaded or viewed and printed in. Heating, venting, air conditioning, and dehumidifying systems. Xerox docuprint 4508 driver has functioned as an interpreter mil hdbk 217 pdf bessel function for engineers n w mclachlan oxford publication free pdf download computer to 8220 talk 8221. Nonexposed lens cable, power, electrical, ignition, high tension webbing, textile, woven nylon missile, guided, design and construction, general specification marking and labeling of us army marine craft marking of electronic items. Users of the handbook will find 16 pages of introductory material, including the table of contents and 42 pages of the actual document itself. This page provides access to us department of defense directives, handbooks and standards related to reliability practices. Mil hdbk 454b 15 april 2007 superseding mil hdbk 454a 3 november 2000 department of defense handbook general guidelines for electronic equipment this handbook is for guidance only. Wbdg is a gateway to uptodate information on integrated whole building design techniques and technologies. Then nasa part applicatios handboon mil std978k has been prepare td o provid ae source of technical informatio for nasn a centers and nasa contractor ans d to maximize standar pard t usage.
Mil hdbk 61a page iii table of contents paragraph page 1. To open a pdf file in your browser, click the filename. Mil hdbk 171f volume 1, foreword table of contents ii foreword 1. Milhdbk263 electrostatic discharge control handbook.
A designated connection, location, or assembly used on an esd protective material or device that is intended to accommodate electrical connection from the device to an esd ground. Name file size ready to use the online process to update qm helps you do what it takes to 20100304 10 17 675283119 aw c adbeilstcs3 wwe. This handbook is approved for use by all departments and agencies. Heating, venting, air conditioning, and dehumidifying systems mil hdbk 1003 3. Mil hdbk 263b electrostatic discharge and electronic control handbook. Table i provides a crossreference listing of mil std1686 requirements, mil hdbk 263 guidance, and mil hdbk 263 supplementary technical data. Electrostatic discharge control and the united states military. Dod hdbk 263 2 may 1980 depak214ent of defense washington, d. Milhdbk1222 guide to the general style and format of u.
Milhdbk1190 facility planning and design guide milhdbk1190 cancellation notice 1 cancelled see the following. Mil hdbk 263 electrostatic discharge control handbook for protection of electrical and electronic parts, assemblies and equipment document center. Ufc310101 milstd3007 show complete document history. This handbook is approved for use by all departments and agencies of the. Contractors shall establish, implement, and document the esd control program in accordance with the requirements of this standard. Army work package technical manuals this handbook is for guidance only. This atenderdlzat ion handbook wae developed by the department of the navy, naval sea. The static dissipative bobbins qualify as electrostatic discharge protective per mil std1686c and. You can enter comments against it by using the link at that site.
This military handbook is approved for use by all departments and agencies of the department of defense dod. This handbook is approved for use by all departments and agencies of the department of defense. The standard is available from global engineering documents, usa and canada 18008547179, international 3033977956. Program in accordance with the requirements of milstd1686. You can then print them out, and assemble the pages as required by the change notices. Architectural electromagnetic shielding handbook, a design and specification guide. Work bench surfaces which contact esds items and personnel have approved esd protective work surfaces or mats and are grounded through a resistive ground cable. Do not cite this document as a requirement amsc na area tmss. Humidity and esd control ground zero electrostatics. The notice pages will be retained as a check sheet. The esd workspace has approved esd protective floor matting. Holders of mil hdbk 217f will verify that page changes and additions indicated have been entered. Handbook manual guide by military specifications and standards. C onfiguration management d ocuments and links eia836, configuration management data exchange and interoperability is published.
1427 977 464 661 115 293 806 1348 701 1177 430 552 503 1012 861 1461 1153 1016 1136 1274 491 1411 1364 199 1183 830 1238 1089 307 1011 893 817 184 186 1029 1116 822 778 661 1425 682 1357 913 376 853